Abstract

One of the fundamental requirements for testing and analysing a Permanent Magnet Synchronous Generator (PMSG) is to obtain its electrical and mechanical parameters. This paper describes the test set up and the procedure for obtaining them. Stator resistance and flux linkage measurements follow IEEE standards. In the other hand a new approach for an alternative stator inductance and inertia measurement is analysed. More precisely, the former is obtained through laboratory work based on the locked rotor test, and the latter through a CAD software based on a 3D model. In order to assess and validate the obtained values, an electromechanical model is derived for validation and contribution of the whole project. Finally, small relative errors between measured and simulated values indicate the functionality of the used methods and of the machine.
Original languageEnglish
Title of host publicationProceedings of the International Conference on Optimization of Electrical and Electronic Equipment, OPTIM 2014
Number of pages6
PublisherIEEE Computer Society Press
Publication dateMay 2014
Pages483-488
Article number6850897
ISBN (Print)9781479951833
DOIs
Publication statusPublished - May 2014
EventInternational Conference on Optimization of Electrical and Electronic Equipment - Brasov, Romania
Duration: 22 May 201424 May 2014
Conference number: 14th

Conference

ConferenceInternational Conference on Optimization of Electrical and Electronic Equipment
Number14th
Country/TerritoryRomania
CityBrasov
Period22/05/201424/05/2014
SeriesOptimization of Electrical and Electronic Equipment (OPTIM), Proceedings
ISSN1842-0133

Keywords

  • Electrical parameters
  • Mechanical parameters
  • Permanent magnet synchronous generator
  • Stator inductance

Fingerprint

Dive into the research topics of 'Alternative parameter determination methods for a PMSG'. Together they form a unique fingerprint.

Cite this