Clinical outcome in patients with implantable cardioverter-defibrillator and cancer: a nationwide study

Anne M Christensen, Jenny Bjerre, Morten Schou, Christian Jons, Michael Vinther, Gunnar H Gislason, Jens B Johansen, Jens C Nielsen, Helen H Petersen, Sam Riahi, Anne-Christine Ruwald

Research output: Contribution to journalJournal articleResearchpeer-review

7 Citations (Scopus)

Abstract

Aims: Patients with cancer are insufficiently represented in randomized clinical trials investigating efficacy of implantable cardioverter-defibrillators (ICDs). We aimed to describe outcomes in patients with a pre-existing diagnosis of cancer at time of ICD implantation.

Methods and results: We utilized Danish nationwide registries to identify primary and secondary prevention ICD implantations from 2007 to 2012. Multivariable Cox models were used to assess the risk of appropriate ICD therapy and mortality in patients with and without cancer at time of implantation. During a median follow-up of 2.1 years, 2935 primary prevention ICD and 2730 secondary prevention ICD implantations were identified. Out of these [289 (5.1%)] had pre-existing cancer [primary 140 (4.8%), secondary 149 (5.5%)]. No differential risk for appropriate ICD therapy was found between patients with or without cancer, [primary cancer: 19/140, no cancer: 380/2795, hazard ratio (HR) = 1.07 (0.67-1.69)] and [secondary cancer: 42/149, no cancer: 699/2581, HR = 1.28 (0.93-1.75)]. In primary patients, cancer was not associated with higher risk of 1-year [cancer: 10/140, no cancer: 133/2795, HR = 1.20 (0.84-2.28)] or all-time mortality [cancer: 22/140, no cancer: 339/2795, HR = 1.13 (0.74-1.75)]. In secondary patients, cancer was associated with a higher 1-year [cancer: 19/149, no cancer: 108/2581, HR = 2.62 (1.60-4.29)] and all-time mortality [cancer: 44/149, no cancer: 315/2581, HR = 2.36 (1.71-3.24)].

Conclusion: Implantable cardioverter-defibrillators were implanted in a minority of cancer patients. No difference in risk of appropriate therapy was observed between cancer and non-cancer patients, regardless of implant indication. Cancer was associated with increased mortality in secondary prevention ICD patients, but not in primary prevention ICD patients. In secondary prevention ICD patients, the majority of deaths were attributable to cancer.

Original languageEnglish
JournalEuropace
Volume21
Issue number3
Pages (from-to)465–474
Number of pages10
ISSN1099-5129
DOIs
Publication statusPublished - 1 Mar 2019

Bibliographical note

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.

Keywords

  • Appropriate implantable cardioverter-defibrillator therapy
  • Heart failure
  • Mortality
  • Oncology
  • Patient selection
  • Prognosis

Fingerprint

Dive into the research topics of 'Clinical outcome in patients with implantable cardioverter-defibrillator and cancer: a nationwide study'. Together they form a unique fingerprint.

Cite this