Concomitant changes in ventricular depolarization and repolarization and long-term outcomes of biventricular pacing

Christoffer Polcwiartek*, Daniel J Friedman, Kasper Emerek, Claus Graff, Peter L Sørensen, Joseph Kisslo, Zak Loring, Steen M Hansen, Kristian Kragholm, Bhupendar Tayal, Svend E Jensen, Peter Søgaard, Christian Torp-Pedersen, Brett D Atwater

*Corresponding author for this work

Research output: Contribution to journalJournal articleResearchpeer-review

34 Downloads (Pure)

Abstract

Background: Biventricular (BiV) pacing increases transmural repolarization heterogeneity due to epicardial to endocardial conduction from the left ventricular (LV) lead. However, limited evidence is available on concomitant changes in ventricular depolarization and repolarization and long-term outcomes of BiV pacing. Therefore, we investigated associations of BiV pacing-induced concomitant changes in ventricular depolarization and repolarization with mortality (i.e., LV assist device, heart transplantation, or all-cause mortality) and sustained ventricular arrhythmia endpoints. Methods: Consecutive BiV-defibrillator recipients with digital preimplantation and postimplantation electrocardiograms recorded between 2006 and 2015 at Duke University Medical Center were included. We calculated changes in QRS duration and corrected JT (JTc) interval and split them by median values. For simplicity, these variables were named QRS decreased (≤ −12 ms), QRS increased (> –12 ms), JTc decreased (≤22 ms), and JTc increased (> 22 ms) and subsequently used to construct four mutually exclusive groups. Results: We included 528 patients (median age, 68 years; male, 69%). No correlation between changes in QRS duration and JTc interval was observed (P =.295). Compared to QRS decreased/JTc increased, increased risk of the composite mortality endpoint was associated with QRS decreased/JTc decreased (hazard ratio [HR] = 1.62; 95% confidence interval [CI] = 1.09-2.43), QRS increased/JTc decreased (HR = 1.86; 95% CI = 1.27-2.71), and QRS increased/JTc increased (HR = 2.25; 95% CI = 1.52-3.35). No QRS/JTc group was associated with excess sustained ventricular arrhythmia risk (P =.400). Conclusion: Among BiV-defibrillator recipients, QRS decreased/JTc increased was associated with the most favorable long-term survival free of LV assist device, heart transplantation, and sustained ventricular arrhythmias. Our findings suggest that improved electrical resynchronization may be achieved by assessing concomitant changes in ventricular depolarization and repolarization.

Original languageEnglish
JournalPacing and Clinical Electrophysiology
Volume43
Issue number11
Pages (from-to)1333-1343
Number of pages11
ISSN0147-8389
DOIs
Publication statusPublished - Nov 2020

Keywords

  • biventricular pacing
  • cardiac resynchronization therapy
  • heart failure
  • implantable cardioverter-defibrillator
  • ventricular arrhythmias
  • ventricular repolarization

Fingerprint

Dive into the research topics of 'Concomitant changes in ventricular depolarization and repolarization and long-term outcomes of biventricular pacing'. Together they form a unique fingerprint.
  • Cardiac Resynchronization

    Graff, C.

    01/03/2016 → …

    Project: Research

Cite this