Abstract
Cone penetration testing (CPT) is a fast and reliable means of conducting site investigations. Different methods exist for soil profile interpretation from CPT data but their validity still needs to be verified. A wind farm site at Aarhus, where numerous CPTu tests have been conducted is considered. The raw cone penetration measurements are scrutinized for data connected with physical or mechanical errors, and these are removed. The corrected data then were used for classifying soil by several charts presented in the literature. The results are further
compared and verified with laboratory classification of samples retrieved from boreholes.
compared and verified with laboratory classification of samples retrieved from boreholes.
| Original language | English |
|---|---|
| Title of host publication | Proceedings of the Twenty-second (2012) International Offshore and Polar Engineering Conference |
| Number of pages | 8 |
| Publisher | International Society of Offshore & Polar Engineers |
| Publication date | 2012 |
| Pages | 151-158 |
| ISBN (Electronic) | 978-1-880653-94−4 |
| Publication status | Published - 2012 |
| Event | International Ocean and Polar Engineering Conference 2012 - Ixia, Rhodes, Greece Duration: 17 Jun 2012 → 23 Jun 2012 Conference number: 22 |
Conference
| Conference | International Ocean and Polar Engineering Conference 2012 |
|---|---|
| Number | 22 |
| Country/Territory | Greece |
| City | Ixia, Rhodes |
| Period | 17/06/2012 → 23/06/2012 |
| Series | Proceedings of the International Offshore and Polar Engineering Conference |
|---|---|
| Number | 22 |
| ISSN | 1098-6189 |
Keywords
- Soil Classification
- Piezocone Penetration Test
- In Situ Testing
- Case Study
Fingerprint
Dive into the research topics of 'CPTu-Based Geotechnical Site Assessment for Offshore Wind Turbines: a Case Study from the Aarhus Site in Denmark'. Together they form a unique fingerprint.Cite this