T1 - Dynamic Pressure Pain Hypersensitivity as Assessed by Roller Pressure Algometry in Episodic Cluster Headache
AU - Palacios-Cena, Maria
AU - Gomez-Mayordomo, Victor
AU - Garcia-Azorin, David
AU - Gonzalez-Garcia, Nuria
AU - Cuadrado, Maria L
AU - Fernandez-de-Las-Penas, Cesar
AU - Arendt-Nielsen, Lars
AU - Guerrero, Angel L
PY - 2020/3
Y1 - 2020/3
N2 - BACKGROUND: A method for assessing dynamic muscle hyperalgesia (dynamic pressure algometry) has been developed and applied in tension-type and migraine headaches.OBJECTIVES: To investigate differences in dynamic pressure pain assessment over the trigeminal area between men with cluster headache (CH) and headache-free controls, and the association between dynamic and static pressure pain sensitivity.STUDY DESIGN: A case-control study.SETTING: Tertiary urban hospital.METHODS: Forty men with episodic CH and 40 matched controls participated. Dynamic pressure pain sensitivity was assessed with a dynamic pressure algometry set consisting of 8 rollers with different fixed levels (500, 700, 850, 1,350, 1,550, 2,200, 3,850, and 5,300 g). Each roller was moved at a speed of 0.5 cm/sec over a diagonal line covering the temporalis muscle from an anterior to posterior direction. The dynamic pressure threshold (DPT; load level of the first painful roller) and the pain intensity perceived at the DPT level (roller-evoked pain) were assessed. Static pressure pain thresholds (PPT) were also assessed with a digital pressure algometer applied statically over the mid-muscle belly of the temporalis. Patients were assessed in a remission phase, at least 3 months from the last cluster attack, and without preventive medication.RESULTS: Side-to-side consistency between DPTs (r = 0.781, P < 0.001), roller-evoked pain on DPT (r = 0.586; P < 0.001), and PPTs (r = 0.874; P < 0.001) were found in men with CH. DPT was moderately, bilaterally, and side-to-side associated with PPTs (0.663 > r > 0.793, all P < 0.001). Men with CH had bilateral lower DPT and PPT and reported higher levels of roller-evoked pain (all P < 0.001) than headache-free controls.LIMITATIONS: Only men with episodic CH were included.CONCLUSIONS: This study supports that a dynamic pressure algometry is as valid as a static pressure algometry for assessing pressure pain sensitivity in patients with CH. Assessing both dynamic and static pain sensitivity may provide new opportunities for differentiated diagnostics.KEY WORDS: Cluster headache, dynamic pressure pain, pressure pain threshold.
AB - BACKGROUND: A method for assessing dynamic muscle hyperalgesia (dynamic pressure algometry) has been developed and applied in tension-type and migraine headaches.OBJECTIVES: To investigate differences in dynamic pressure pain assessment over the trigeminal area between men with cluster headache (CH) and headache-free controls, and the association between dynamic and static pressure pain sensitivity.STUDY DESIGN: A case-control study.SETTING: Tertiary urban hospital.METHODS: Forty men with episodic CH and 40 matched controls participated. Dynamic pressure pain sensitivity was assessed with a dynamic pressure algometry set consisting of 8 rollers with different fixed levels (500, 700, 850, 1,350, 1,550, 2,200, 3,850, and 5,300 g). Each roller was moved at a speed of 0.5 cm/sec over a diagonal line covering the temporalis muscle from an anterior to posterior direction. The dynamic pressure threshold (DPT; load level of the first painful roller) and the pain intensity perceived at the DPT level (roller-evoked pain) were assessed. Static pressure pain thresholds (PPT) were also assessed with a digital pressure algometer applied statically over the mid-muscle belly of the temporalis. Patients were assessed in a remission phase, at least 3 months from the last cluster attack, and without preventive medication.RESULTS: Side-to-side consistency between DPTs (r = 0.781, P < 0.001), roller-evoked pain on DPT (r = 0.586; P < 0.001), and PPTs (r = 0.874; P < 0.001) were found in men with CH. DPT was moderately, bilaterally, and side-to-side associated with PPTs (0.663 > r > 0.793, all P < 0.001). Men with CH had bilateral lower DPT and PPT and reported higher levels of roller-evoked pain (all P < 0.001) than headache-free controls.LIMITATIONS: Only men with episodic CH were included.CONCLUSIONS: This study supports that a dynamic pressure algometry is as valid as a static pressure algometry for assessing pressure pain sensitivity in patients with CH. Assessing both dynamic and static pain sensitivity may provide new opportunities for differentiated diagnostics.KEY WORDS: Cluster headache, dynamic pressure pain, pressure pain threshold.
KW - Cluster headache
KW - Dynamic pressure pain
KW - Pressure pain threshold
UR - http://www.scopus.com/inward/record.url?scp=85082490376&partnerID=8YFLogxK
M3 - Journal article
C2 - 32214304
SN - 1533-3159
VL - 23
SP - 219
EP - 227
JO - Pain Physician
JF - Pain Physician
IS - 2
ER -