Effectiveness of CRT-D Versus ICD on Prevention of Electrical Storm: Big Data from the USA

Saeed Shakibfar*, MohammadReza Yazdchi, Susan Aliakbary Hosseinabadi

*Corresponding author for this work

Research output: Contribution to book/anthology/report/conference proceedingArticle in proceedingResearchpeer-review

Abstract

Patients with implantable cardioverter-defibrillator (ICD) are at the risk of electrical storm (ES) occurrence associated with mortality and poor quality of life. Cardiac resynchronization therapy with defibrillator (CRT-D) minimizes inappropriate ICD shocks. However, limited reports exist on the impact of CRT-D versus traditional ICD on ES occurrences in real-life cohorts. We evaluated the implanted-device characteristics associated with ES events in a large data based on daily stored device-summaries obtained from remote monitoring data in US.Between 2004 and 2016, 19,935 US patients were implanted. Survival analyses with Cox regression for device-shock therapy were performed between patients who experienced at least one ES and those without ES. CRT-D devices (bi-ventricular) were implanted in 5522 (28%) patients during this period, and their ES events over time were compared to ICD recipients implanted with RV lead. Primary endpoint was the first ES event.ES occurred with the rate of 7.26% for all patients during the period. Cox regression analyses revealed significantly an increase risk in ES occurrences (the p-value < 0.05 and hazard ratio >> 1) with shock therapy. CRT-D implant led to lower ES risk comparing with patients received traditional ICD (RV only).

Original languageEnglish
Title of host publication 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Number of pages3
PublisherIEEE
Publication date2019
Pages302-304
Article number8857530
ISBN (Print)978-1-5386-1312-2
ISBN (Electronic)978-1-5386-1311-5
DOIs
Publication statusPublished - 2019
EventAnnual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC - Berlin, Germany
Duration: 23 Jul 201927 Jul 2019
Conference number: 41

Conference

ConferenceAnnual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC
Number41
Country/TerritoryGermany
CityBerlin
Period23/07/201927/07/2019
SeriesI E E E Engineering in Medicine and Biology Society. Conference Proceedings
ISSN2375-7477

Fingerprint

Dive into the research topics of 'Effectiveness of CRT-D Versus ICD on Prevention of Electrical Storm: Big Data from the USA'. Together they form a unique fingerprint.

Cite this