TY - JOUR
T1 - Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage Conditions
AU - Reyes, M.
AU - Rodriguez, Pedro
AU - Vazquez, S.
AU - Luna, A.
AU - Teodorescu, Remus
AU - Carrasco, J. M.
PY - 2012
Y1 - 2012
N2 - In the last few years, restrictive grid codes have arisen to ensure the performance and stability of electrical networks, which experience a massive integration of renewable energy sources and distributed generation systems that are normally connected to the grid through electronic power converters. In these codes, the injection of positive- and negative-sequence current components becomes necessary for fulfilling, among others, the low-voltage ride-through requirements during balanced and unbalanced grid faults. However, the performance of classical dq current controllers, applied to power converters, under unbalanced grid-voltage conditions is highly deficient, due to the unavoidable appearance of current oscillations. This paper analyzes the performance of the double synchronous reference frame controller and improves its structure by adding a decoupling network for estimating and compensating the undesirable current oscillations. Experimental results will demonstrate the validity of the proposed decoupled DSRF controller.
AB - In the last few years, restrictive grid codes have arisen to ensure the performance and stability of electrical networks, which experience a massive integration of renewable energy sources and distributed generation systems that are normally connected to the grid through electronic power converters. In these codes, the injection of positive- and negative-sequence current components becomes necessary for fulfilling, among others, the low-voltage ride-through requirements during balanced and unbalanced grid faults. However, the performance of classical dq current controllers, applied to power converters, under unbalanced grid-voltage conditions is highly deficient, due to the unavoidable appearance of current oscillations. This paper analyzes the performance of the double synchronous reference frame controller and improves its structure by adding a decoupling network for estimating and compensating the undesirable current oscillations. Experimental results will demonstrate the validity of the proposed decoupled DSRF controller.
UR - http://www.scopus.com/inward/record.url?scp=84861432083&partnerID=8YFLogxK
U2 - 10.1109/TPEL.2012.2190147
DO - 10.1109/TPEL.2012.2190147
M3 - Journal article
SN - 0885-8993
VL - 27
SP - 3934
EP - 3943
JO - I E E E Transactions on Power Electronics
JF - I E E E Transactions on Power Electronics
IS - 9
ER -