TY - GEN
T1 - Examinations of ZnO-varistors in the leakage region with regard to high frequency stresses
AU - Bak-Jensen, J.
AU - Bak-Jensen, B.
AU - Mikkelsen, S. Damsgaard
AU - Sorensen, J. Tolstrup
PY - 1993
Y1 - 1993
N2 - ZnO-varistors and ZnO-arresters are widely used for protection of HVDC-systems and switch-mode power supplies. Because of high frequency components in the leakage current, a model of the leakage region of a ZnO-arrester is of interest. In this paper an equivalent circuit model for the leakage region of a ZnO-arrester is set up. The model is able to describe the frequency, current and temperature dependency of the arrester in the leakage region. The lumped parameters of the model is achieved from tests with frequency sweep analysis, FFT-analysis and DC-resistance measurements at different temperatures. The method for determination of the lumped parameters of the equivalent circuit model is verified by tests on a ZnO-varistor, and the validity of the parameters is tested by parametric simulations. The set up method gives stable parameters and it is possible to simulate a measured voltage with high frequency components from a measured current signal with reasonable accuracy.
AB - ZnO-varistors and ZnO-arresters are widely used for protection of HVDC-systems and switch-mode power supplies. Because of high frequency components in the leakage current, a model of the leakage region of a ZnO-arrester is of interest. In this paper an equivalent circuit model for the leakage region of a ZnO-arrester is set up. The model is able to describe the frequency, current and temperature dependency of the arrester in the leakage region. The lumped parameters of the model is achieved from tests with frequency sweep analysis, FFT-analysis and DC-resistance measurements at different temperatures. The method for determination of the lumped parameters of the equivalent circuit model is verified by tests on a ZnO-varistor, and the validity of the parameters is tested by parametric simulations. The set up method gives stable parameters and it is possible to simulate a measured voltage with high frequency components from a measured current signal with reasonable accuracy.
UR - https://www.scopus.com/pages/publications/0027835056
M3 - Article in proceeding
AN - SCOPUS:0027835056
SN - 0852965907
T3 - IEE Conference Publication
SP - 191
EP - 196
BT - Power Electronics in Generation and Transmission
A2 - Anon, null
PB - Publ by IEE
T2 - Proceedings of the 5th European Conference on Power Electronics and Applications
Y2 - 13 September 1993 through 16 September 1993
ER -