Fault Current Calculation for Inverter-interfaced Power Sources Considering Saturation Element

Zhe Yang, Qi Zhang, Zhou Liu, Zhe Chen

Research output: Contribution to book/anthology/report/conference proceedingArticle in proceedingResearchpeer-review

3 Citations (Scopus)

Abstract

The fault current of converter-interfaced renewable energy sources (CIRESs) is mainly determined by the control system of the inverter, so the traditional calculation method of short-circuit current based on voltage-flux is no longer applicable. A typical control system of CIRESs is established by coordinate transformation from abc frame to dq frame. Through the tuning of PI parameters, the second order system is reduced to the first order system, and the fault current is calculated using transfer function. After that, the impact of the saturation element on transient current is analyzed. The fault current at this time is divided into two stages according to whether the saturation element is working or not, and the specific moment when the input signal exits the saturation region is calculated. When the input signal enters the saturation region, the output of the saturation element is a constant value, so the short-circuit current can still be seen as a step response. At the second stage, the fault current can be regarded as the superposition of zero input response and zero state response. The classical method of linear control theory is used to calculate the fault current for the system with a nonlinear link, so it is easy for industrial application due to the small amount of calculation. In addition, the transient current peak value and its occurrence time calculated by this method are basically equal to the simulation results, and this proves the effectiveness of the proposed method.
Original languageEnglish
Title of host publicationProceedings of 2021 IEEE 4th International Electrical and Energy Conference, CIEEC 2021
Publication date2021
Pages1-5
Article number9510234
ISBN (Print)978-1-7281-7150-0
ISBN (Electronic)978-1-7281-7149-4
DOIs
Publication statusPublished - 2021
Event2021 IEEE 4th International Electrical and Energy Conference (CIEEC) - Wuhan, China
Duration: 28 May 202130 May 2021

Conference

Conference2021 IEEE 4th International Electrical and Energy Conference (CIEEC)
Country/TerritoryChina
CityWuhan
Period28/05/202130/05/2021

Keywords

  • CIRESs
  • saturation element
  • transient current
  • zero input response

Fingerprint

Dive into the research topics of 'Fault Current Calculation for Inverter-interfaced Power Sources Considering Saturation Element'. Together they form a unique fingerprint.

Cite this