Skip to main navigation Skip to search Skip to main content

Haemodynamic effects of low versus high dialysate temperature in haemodialysis patients: a single-blinded, randomised, cross-over study

  • Ina Ejsing Hunnerup Jørgensen*
  • , Jonas Schandorph Kaalund Jensen
  • , Niels Henrik Buus
  • , Jens Dam Jensen
  • , Christian Daugaard Peters
  • *Corresponding author for this work

Research output: Contribution to journal › Journal article › Research › peer-review

Abstract

Background: Cooling of the dialysate may improve intradialytic haemodynamics. This study compared low dialysate temperature (LDT) of 35 °C with high dialysate temperature (HDT) of 37 °C (standard) in terms of blood pressure (BP), intradialytic haemodynamics, and orthostatic BP. Methods: In a single-blind, randomised, controlled, crossover study fourteen haemodialysis (HD) patients underwent a 4-h HD session with LDT (35 °C) or HDT (37 °C) separated by a 1- week interval. BP was monitored throughout HD. Intradialytic haemodynamics were assessed with ultrasound dilution technique (Transonic). Orthostatic BP was measured pre- and postHD. Results: Ultrafiltration (mean with 95% confidence interval) was similar (LDT: 2.6(2.3;2.9) vs. HDT: 2.5(2.0;3.1) liters). Arterial line temperature as a marker of body temperature remained stable with LDT but increased with HDT (mean change LDT: 0.0(-0.2;0.1) vs. HDT: 0.4(0.2;0.6)°C) with a mean between intervention difference of -0.4(-0.6;-0.3)°C. BP remained relatively stable on LDT, whereas HDT caused a significantly larger fall in systolic BP. The mean (± SD) fall in intradialytic systolic BP (PreHD vs. lowest intradialytic) was 20.3 ± 10.5 mmHg (HDT) and 9.6 ± 8.8 mmHg (LDT) with a mean between intervention difference of 10.7(3.2; 17.9) mmHg. LDT caused a significantly lower intradialytic heart rate which by the end of dialysis (after 230 min) on average was − 6.6(-13.0;-0.2) beats/min lower than HDT. Overall, the intradialytic hemodynamic response was similar except for a trend towards higher peripheral resistance and central blood volume with LDT. There was a significantly greater fall in orthostatic systolic BP after dialysis compared with preHD, but there was no significant difference between interventions and the frequency of orthostatic hypotension postHD was also similar (HDT: 54% and LDT: 43%; P = 0.57). Conclusion: Cooler vs. standard dialysate temperature resulted in significantly higher intradialytic BP but had no significant impact on orthostatic BP response postHD. Trial registration: The study was registered at ClinicalTrials.gov where the full study protocol is available (NCT05052151). Registration date was 26/08 2021.

Original languageEnglish
Article number461
JournalBMC Nephrology
Volume27
Issue number1
Number of pages13
ISSN1471-2369
DOIs
Publication statusE-pub ahead of print - 3 Jun 2026

Bibliographical note

© 2026. The Author(s).

Keywords

  • Blood pressure
  • Chronic renal failure
  • Dialysis
  • Haemodynamics
  • Temperature

Fingerprint

Dive into the research topics of 'Haemodynamic effects of low versus high dialysate temperature in haemodialysis patients: a single-blinded, randomised, cross-over study'. Together they form a unique fingerprint.