Hemodynamic effects of low versus high dialysate bicarbonate concentration in hemodialysis patients

Jonas Schandorph Kaalund Jensen*, Ina Hunnerup Jørgensen, Niels Henrik Buus, Jens Dam Jensen, Christian Daugaard Peters

*Corresponding author for this work

Research output: Contribution to journalJournal articleResearchpeer-review

53 Downloads (Pure)

Abstract

INTRODUCTION: Hemodialysis treatment using standard dialysate bicarbonate concentrations cause transient metabolic alkalosis possibly associated with hemodynamic instability. The aim of this study was to perform a detailed comparison of high and low dialysate bicarbonate in terms of blood pressure, intradialytic hemodynamic parameters, orthostatic blood pressure, and electrolytes.

METHODS: Fifteen hemodialysis patients were examined in a single-blind, randomized, controlled, crossover study. Participants underwent a 4-h hemodialysis session with dialysate bicarbonate concentration of 30 or 38 mmol/L with 1 week between interventions. Blood pressure was monitored throughout hemodialysis, while cardiac output, total peripheral resistance, stroke volume, and central blood volume were assessed with ultrasound dilution technique (Transonic). Orthostatic blood pressure was measured pre- and post-hemodialysis.

FINDINGS: With similar ultrafiltration (UF) volume (2.6 L), systolic blood pressure (SBP) tended to decrease more during high dialysate bicarbonate compared to low dialysate bicarbonate; the mean (95% confidence interval) between treatment differences in SBP were: 8 (-4; 20) mmHg (end of hemodialysis) and 7 (0; 15) mmHg (post-hemodialysis). Stroke volume decreased whereas total peripheral resistance increased significantly more during high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment differences: Stroke volume: 12 (1; 23) mL; Total peripheral resistance: -2.9 (-5.3; -0.5) mmHg/(L/min). Cardiac output tended to decrease more with high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment difference 0.7 (0.0; 1.4) L/min. High dialysate bicarbonate caused alkalosis, hypocalcemia, and lower plasma potassium, whereas patients remained normocalcemic with normal pH during low dialysate bicarbonate. Orthostatic blood pressure response after dialysis did not differ significantly.

DISCUSSION: The use of high dialysate bicarbonate compared to low dialysate bicarbonate was associated with hypocalcemia, alkalosis, and a more pronounced hypokalemia. During hemodialysis with UF, a better preservation of blood pressure, stroke volume, and cardiac output may be achieved with low dialysate bicarbonate compared to high dialysate bicarbonate.

Original languageEnglish
JournalHemodialysis International
Volume28
Issue number3
Pages (from-to)290-303
Number of pages14
ISSN1492-7535
DOIs
Publication statusPublished - Jul 2024

Bibliographical note

© 2024 The Author(s). Hemodialysis International published by Wiley Periodicals LLC on behalf of International Society for Hemodialysis.

Keywords

  • Adult
  • Aged
  • Bicarbonates/pharmacology
  • Blood Pressure/drug effects
  • Cross-Over Studies
  • Dialysis Solutions/pharmacology
  • Female
  • Hemodynamics/drug effects
  • Humans
  • Kidney Failure, Chronic/therapy
  • Male
  • Middle Aged
  • Renal Dialysis/methods
  • Single-Blind Method
  • dialysis
  • blood pressure
  • chronic renal failure
  • dialysate solutions
  • hemodialysis solutions
  • bicarbonate

Fingerprint

Dive into the research topics of 'Hemodynamic effects of low versus high dialysate bicarbonate concentration in hemodialysis patients'. Together they form a unique fingerprint.

Cite this