Abstract
High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses to be injected before the position may be estimated. In this paper, a single pulse zero voltage injection method is proposed. The rotor position is directly estimated from the current ripple at half of the switching frequency. No machine parameters are needed and using of filters is avoided. This results in a fast current regulation performance. Injection of zero voltage also minimizes the inverter voltage error effects caused by the dead-time.
Original language | English |
---|---|
Title of host publication | Proceedings of the International Conference on Electrical Machines and Systems, ICEMS 2014 |
Number of pages | 7 |
Publisher | IEEE Press |
Publication date | Oct 2014 |
Pages | 3546-3552 |
DOIs | |
Publication status | Published - Oct 2014 |
Event | 17th International Conference on Electrical Machines and Systems, ICEMS 2014 - Hangzhou, China Duration: 22 Oct 2014 → 25 Oct 2014 |
Conference
Conference | 17th International Conference on Electrical Machines and Systems, ICEMS 2014 |
---|---|
Country/Territory | China |
City | Hangzhou |
Period | 22/10/2014 → 25/10/2014 |