Improved Over-the-air Phased Array Calibration Based on Measured Complex Array Signals

Fengchun Zhang, Wei Fan, Zhengpeng Wang, Yusheng Zhang, Gert Frølund Pedersen

Research output: Contribution to journalJournal articleResearchpeer-review

29 Citations (Scopus)
629 Downloads (Pure)

Abstract

This letter presents an improved phased array calibration method based on measured complex array signals with one single probe. All the phased array elements are excited simultaneously in the measurement, and only phase reverse of each element is required. The error on the first antenna element of the reference method is analyzed, which shows it is accumulated as the array size increases. One more measurement with designed element phase settings is introduced to overcome the deficiency. The improved method shows that only $N+1$ measurements are required to calibrate $N$ antenna elements accurately. Finally, a $4\times 8$ antenna array composed of 4-ridged horn antennas operating at 3.5 GHz was measured to validate the effectiveness of the improved algorithm.

Original languageEnglish
Article number8693562
JournalI E E E Antennas and Wireless Propagation Letters
Volume18
Issue number6
Pages (from-to)1174-1178
Number of pages5
ISSN1536-1225
DOIs
Publication statusPublished - 1 Jun 2019

Keywords

  • Complex signal measurement
  • over-the-air (OTA) testing
  • phased array calibration

Fingerprint

Dive into the research topics of 'Improved Over-the-air Phased Array Calibration Based on Measured Complex Array Signals'. Together they form a unique fingerprint.

Cite this