Abstract

Due to the large surface of the PV generator, its stray capacity with respect to the ground reaches values that can be quite high. When no transformer is used in a grid-connected PV system, common-mode current, which caused by the common mode voltage, can flow through the stray capacitance between the PV array and the ground. It is quite harmful to the body safety and PV system. In order to avoid leakage current, different inverter topologies that generate no varying common-mode voltages, such as bipolar pulse-width modulation (PWM) full-bridge topology, NPC topology have been proposed. From the safety and energy saving viewpoint, it is necessary to develop a higher efficiency topology. In this paper, the generation mechanism of common mode current is discussed. Then different methods used to eliminate the leakage current are compared. Finally, the full-bridge which generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full-bridge is given. The proposed topology has been verified in the simulation based on MATLAB with satisfactory results.
Original languageEnglish
Title of host publicationProceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008
Number of pages5
PublisherIEEE
Publication date2009
Pages285-289
ISBN (Print)978-1-4244-1887-9
DOIs
Publication statusPublished - 2009
EventIEEE International Conference on Sustainable Energy Technologies, ICSET 2008 - , Singapore
Duration: 24 Nov 200827 Nov 2008

Conference

ConferenceIEEE International Conference on Sustainable Energy Technologies, ICSET 2008
CountrySingapore
Period24/11/200827/11/2008

Fingerprint

Leakage currents
Topology
Electric potential
Pulse width modulation
MATLAB
Energy conservation
Capacitance

Cite this

Ma, L., Tang, F., Zhou, F., Jin, X., & Tong, Y. (2009). Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid. In Proceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008 (pp. 285-289). IEEE. https://doi.org/10.1109/ICSET.2008.4747018
Ma, Lin ; Tang, F. ; Zhou, F. ; Jin, X. ; Tong, Y. / Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid. Proceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008. IEEE, 2009. pp. 285-289
@inproceedings{37e37ee096fa11de802f000ea68e967b,
title = "Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid",
abstract = "Due to the large surface of the PV generator, its stray capacity with respect to the ground reaches values that can be quite high. When no transformer is used in a grid-connected PV system, common-mode current, which caused by the common mode voltage, can flow through the stray capacitance between the PV array and the ground. It is quite harmful to the body safety and PV system. In order to avoid leakage current, different inverter topologies that generate no varying common-mode voltages, such as bipolar pulse-width modulation (PWM) full-bridge topology, NPC topology have been proposed. From the safety and energy saving viewpoint, it is necessary to develop a higher efficiency topology. In this paper, the generation mechanism of common mode current is discussed. Then different methods used to eliminate the leakage current are compared. Finally, the full-bridge which generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full-bridge is given. The proposed topology has been verified in the simulation based on MATLAB with satisfactory results.",
author = "Lin Ma and F. Tang and F. Zhou and X. Jin and Y. Tong",
year = "2009",
doi = "10.1109/ICSET.2008.4747018",
language = "English",
isbn = "978-1-4244-1887-9",
pages = "285--289",
booktitle = "Proceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008",
publisher = "IEEE",
address = "United States",

}

Ma, L, Tang, F, Zhou, F, Jin, X & Tong, Y 2009, Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid. in Proceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008. IEEE, pp. 285-289, Singapore, 24/11/2008. https://doi.org/10.1109/ICSET.2008.4747018

Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid. / Ma, Lin; Tang, F.; Zhou, F.; Jin, X.; Tong, Y.

Proceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008. IEEE, 2009. p. 285-289.

Research output: Contribution to book/anthology/report/conference proceedingArticle in proceedingResearchpeer-review

TY - GEN

T1 - Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid

AU - Ma, Lin

AU - Tang, F.

AU - Zhou, F.

AU - Jin, X.

AU - Tong, Y.

PY - 2009

Y1 - 2009

N2 - Due to the large surface of the PV generator, its stray capacity with respect to the ground reaches values that can be quite high. When no transformer is used in a grid-connected PV system, common-mode current, which caused by the common mode voltage, can flow through the stray capacitance between the PV array and the ground. It is quite harmful to the body safety and PV system. In order to avoid leakage current, different inverter topologies that generate no varying common-mode voltages, such as bipolar pulse-width modulation (PWM) full-bridge topology, NPC topology have been proposed. From the safety and energy saving viewpoint, it is necessary to develop a higher efficiency topology. In this paper, the generation mechanism of common mode current is discussed. Then different methods used to eliminate the leakage current are compared. Finally, the full-bridge which generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full-bridge is given. The proposed topology has been verified in the simulation based on MATLAB with satisfactory results.

AB - Due to the large surface of the PV generator, its stray capacity with respect to the ground reaches values that can be quite high. When no transformer is used in a grid-connected PV system, common-mode current, which caused by the common mode voltage, can flow through the stray capacitance between the PV array and the ground. It is quite harmful to the body safety and PV system. In order to avoid leakage current, different inverter topologies that generate no varying common-mode voltages, such as bipolar pulse-width modulation (PWM) full-bridge topology, NPC topology have been proposed. From the safety and energy saving viewpoint, it is necessary to develop a higher efficiency topology. In this paper, the generation mechanism of common mode current is discussed. Then different methods used to eliminate the leakage current are compared. Finally, the full-bridge which generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full-bridge is given. The proposed topology has been verified in the simulation based on MATLAB with satisfactory results.

U2 - 10.1109/ICSET.2008.4747018

DO - 10.1109/ICSET.2008.4747018

M3 - Article in proceeding

SN - 978-1-4244-1887-9

SP - 285

EP - 289

BT - Proceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008

PB - IEEE

ER -

Ma L, Tang F, Zhou F, Jin X, Tong Y. Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid. In Proceedings of IEEE International Conference on Sustainable Energy Technologies, ICSET 2008. IEEE. 2009. p. 285-289 https://doi.org/10.1109/ICSET.2008.4747018