N2 - A new local current-based fast high impedance fault (HIF) detection scheme for DC microgrid clusters using mathematical morphology (MM) is proposed in this paper. The proposed strategy consists of two MM based parts. The first part is MM erosion filtering to extract the current signals and its components to extract the differential feature vector. The second part is MM regional maxima, for defining a determinative value to detect faults in a line segment by the lowest possible time. This scheme also uses local measured values to eliminate the need for communication channels, which provide a low cost, reliable, and fast fault detection method for DC microgrid clusters. Moreover, to provide an accurate HIF detection method, the accurate HIF model in DC systems is presented and used in the proposed method. For demonstrating the efficiency, authenticity, and compatibility of the proposed method, digital time-domain simulations are carried out in MATLAB/Simulink environment under different scenarios such as overload, noise, low and HIFs to distinguish between overloads and HIFs, and the results are compared with several reported algorithms. The obtained simulation results are verified by experimental tests, which validate the proposed strategy's accuracy and speed under different conditions.
AB - A new local current-based fast high impedance fault (HIF) detection scheme for DC microgrid clusters using mathematical morphology (MM) is proposed in this paper. The proposed strategy consists of two MM based parts. The first part is MM erosion filtering to extract the current signals and its components to extract the differential feature vector. The second part is MM regional maxima, for defining a determinative value to detect faults in a line segment by the lowest possible time. This scheme also uses local measured values to eliminate the need for communication channels, which provide a low cost, reliable, and fast fault detection method for DC microgrid clusters. Moreover, to provide an accurate HIF detection method, the accurate HIF model in DC systems is presented and used in the proposed method. For demonstrating the efficiency, authenticity, and compatibility of the proposed method, digital time-domain simulations are carried out in MATLAB/Simulink environment under different scenarios such as overload, noise, low and HIFs to distinguish between overloads and HIFs, and the results are compared with several reported algorithms. The obtained simulation results are verified by experimental tests, which validate the proposed strategy's accuracy and speed under different conditions.
UR - http://www.scopus.com/inward/record.url?scp=85097092862&partnerID=8YFLogxK
U2 - 10.1016/j.epsr.2020.106981
DO - 10.1016/j.epsr.2020.106981
M3 - Journal article
AN - SCOPUS:85097092862
VL - 192
JO - Electric Power Systems Research
JF - Electric Power Systems Research
SN - 0378-7796
M1 - 106981
ER -