Skip to main navigation Skip to search Skip to main content

Oral anticoagulant management of patients with mechanical heart valves at the Salam Centre of Khartoum: Observations on quality of anticoagulation and thrombotic risk

  • Nicoletta Erba
  • , Alberto Tosetto
  • , Martin Langer
  • , Suha Abdelwahab Abdallah
  • , Elena Giovanella
  • , Salvatore Lentini
  • , Franco Masini
  • , Alessandro Mocini
  • , Gennarina Portella
  • , Alessandro Cristian Salvati
  • , Alessandro Squizzato
  • , Sophie Testa
  • , Gregory Y. H. Lip
  • , Daniela Poli*
  • *Corresponding author for this work

Research output: Contribution to journal › Journal article › Research › peer-review

152 Downloads (Pure)

Abstract

INTRODUCTION: Rheumatic heart disease with mechanical heart valve (MHV) replacement is common in Africa. However, MHV requires long-life anticoagulation and managing this can be challenging.

METHODS AND RESULTS: We report data of a prospective observational study conducted between August 2018 and September 2019 in MHV patients in the Salam Centre for Cardiac Surgery built in Khartoum, by Emergency, an Italian Non-Governmental Organization, to evaluate the quality of anticoagulation control and the risk of thrombotic complications.

RESULTS: We studied 3647 patients (median age 25.1 years; 53.9 % female). Median Time in Therapeutic Range (TTR) was 53 % (interquartile range 37 % to 67 %) and 70 thrombotic events (rate 1.8 × 100 pt-years [95 % CI 1.38-2.23]) were recorded. Among patients in the first quartile of TTR (≤37 %), we recorded 34/70 (48.6 %) of all thrombotic events (rate 3.7 × 100 pt-years [95 % CI 2.5-5.1]), with a high mortality rate (2.2 × 100 pt-years [95 % CI 1.3-3.3]). In patients with guideline-recommended TTR (≥65 %) the event rate was 0.8 × 100 pt-years for thrombotic events [95 % CI 0.3-1.5] and 0.4 × 100 pt-years for mortality [95 % CI 0.1-0.9]. Multivariable analysis showed that having a TTR in the lowest quartile (≤37 %) and being noncompliant are significantly associated with increased thrombotic risk. Aspirin use or different valve type did not influence the thrombotic risk. Almost 40 % of all thromboembolic complications could have been potentially prevented by further improving VKA management to obtain a TTR > 37 %.

CONCLUSION: The thrombotic risk of MHV patients on VKAs living in a low-income country like Sudan is associated with low quality of anticoagulation control. Efforts should be made to decrease the number of non-compliant patients and to reach a guideline-recommended TTR of ≥65 %.

Original languageEnglish
JournalThrombosis Research
Volume219
Pages (from-to)155-161
Number of pages7
ISSN0049-3848
DOIs
Publication statusPublished - Nov 2022

Bibliographical note

Copyright © 2022 The Authors. Published by Elsevier Ltd.. All rights reserved.

Keywords

  • Adult
  • Anticoagulants/adverse effects
  • Aspirin/pharmacology
  • Blood Coagulation
  • Female
  • Heart Valves
  • Hemorrhage/chemically induced
  • Humans
  • Male
  • Thrombosis/chemically induced
  • Warfarin
  • Africa
  • Oral anticoagulants
  • Mechanical heart valves
  • Thrombotic risk

Fingerprint

Dive into the research topics of 'Oral anticoagulant management of patients with mechanical heart valves at the Salam Centre of Khartoum: Observations on quality of anticoagulation and thrombotic risk'. Together they form a unique fingerprint.

Cite this