Abstract
This paper proposes a new method for the real-time condition monitoring of IGBT modules in PV inverter system. The proposed method uses only one monitoring parameter, VCE_ON and the wear-out failure modes of IGBT modules, bond-wire fatigue and solder joint fatigue can be distinguished by the VCE_ON values at two measurement points. Thus, it is cost-effective compared with using one more monitoring parameter in order to separate failure modes. Furthermore, the proposed method does not require re-characterizations of IGBT modules as it is worn out. Experimental results verify the validity and feasibility of the proposed method.
Original language | English |
---|---|
Title of host publication | Proceedings of CIPS 2018; the 10th International Conference on Integrated Power Electronics Systems |
Number of pages | 5 |
Place of Publication | Germany |
Publisher | VDE Verlag GMBH |
Publication date | Mar 2018 |
Pages | 412-416 |
ISBN (Print) | 978-3-8007-4540-1 |
Publication status | Published - Mar 2018 |
Event | CIPS 2018 - 10th International Conference on Integrated Power Electronics Systems - Stuttgart, Germany Duration: 20 Mar 2018 → 22 Mar 2018 |
Conference
Conference | CIPS 2018 - 10th International Conference on Integrated Power Electronics Systems |
---|---|
Country/Territory | Germany |
City | Stuttgart |
Period | 20/03/2018 → 22/03/2018 |