Abstract
The converter behavior in harmonic studies or harmonic stability analysis can be evaluated by its output impedance. In order to overcome the nonlinearities introduced by the PLL, linearized models around the operating point are typically used. However, in the case of an imbalance in the system the dq signals are not dc anymore, and therefore, linearization cannot be done. In this paper a Decoupled Double Synchronous Frame PLL is used to eliminate the oscillations in the dq frame signals. The small signal model of this PLL including an unbalanced current controller is presented in this paper.
Original language | English |
---|---|
Title of host publication | Proceedings of IEEE 17th Workshop on Control and Modeling for Power Electronics (COMPEL), 2016 |
Number of pages | 6 |
Publisher | IEEE Press |
Publication date | Jun 2016 |
ISBN (Electronic) | 978-1-5090-1815-4 |
DOIs | |
Publication status | Published - Jun 2016 |
Event | 2016 IEEE COMPEL - Trondheim, Norway Duration: 28 Jun 2016 → 1 Jul 2016 |
Conference
Conference | 2016 IEEE COMPEL |
---|---|
Country/Territory | Norway |
City | Trondheim |
Period | 28/06/2016 → 01/07/2016 |
Keywords
- Phase locked loop
- Current control
- Harmonic studies