Abstract
The lengths of the bored piles varied from 2 m to 6 m and all were of a diameter of 140 mm. The piles were tested to failure in tension and the load-displacement relations were recorded. The investigation has shown pronounced differences between the load bearing capacities obtained by different design methods. The methods proposed by Fleming et al. and Reese & O’Neill seem to produce the best match with the test results.
Translated title of the contribution | Trækforsøg med borede pæle i sand |
---|---|
Original language | English |
Title of host publication | ELU-ULS 2006 : International symposium on ultimate limit states of geotechnical structures |
Number of pages | 8 |
Publisher | Laboratoire Central des Ponts et Chaussées |
Publication date | 2006 |
Pages | 87-94 |
ISBN (Print) | 2720824682 |
Publication status | Published - 2006 |
Event | International symposium on ultimate limit states of geotechnical structures - Paris, France Duration: 23 Aug 2006 → 25 Aug 2006 |
Conference
Conference | International symposium on ultimate limit states of geotechnical structures |
---|---|
Country/Territory | France |
City | Paris |
Period | 23/08/2006 → 25/08/2006 |
Keywords
- Soil Conditions
- Earth Pressure
- Plastic Zone
- Finite Element Modeling
- Uplift Capacity