The effects of wind-driven rain on the hygrothermal conditions behind wooden beam ends and at the interfaces between internal insulation and existing solid masonry

Tessa Kvist Hansen*, Søren Peter Bjarløv, Ruut Hannele Peuhkuri

*Corresponding author for this work

Research output: Contribution to journalJournal articleResearchpeer-review

19 Citations (Scopus)
38 Downloads (Pure)

Abstract

An inevitable measure when energy retrofitting historic buildings in Europe, is the reduction of building envelope heat loss. On preservation-worthy facades where external insulation is not an option, installation of internal insulation is gaining pace. The historic buildings in Denmark are often constructed with solid masonry facades and wooden decks. The internal insulation may, however, entail potential hygrothermal risks in walls and embedded wood. Measures such as vapour barriers and capillary active insulation materials are continuously evolving and the subject of much current research. The hygrothermal conditions are of great importance for the durability of the building constructions, and for the health and wellbeing of occupants. Wind-driven rain (WDR) is a central factor contributing to water penetration and moisture loads of the exterior walls. Numerous studies have shown that WDR loads influence the moisture conditions in masonry walls and embedded wooden beams, and can even affect interior relative humidity. In the present paper WDR loads on existing façades in a cold temperate climate were determined by measurements and compared to a semi-empirical model. Simultaneously, the hygrothermal conditions within internally insulated walls with exposed brick and embedded wooden beams were monitored. Furthermore, numerical simulations were implemented for clarification of WDR impact. Hygrothermal simulations and previous studies, inevitably show that high WDR loads result in higher moisture content behind the interior insulation. Results from the field measurements of WDR however, cannot directly be referred to the moisture content measured in walls behind interior insulation or beam ends. However, fluctuations in external air humidity proved to be influential on condiditons in the construction. Implementation of a semi-empirical model for calculations of WDR agreed with previous studies in predictions being too conservative when compared to measured WDR.
Original languageEnglish
JournalEnergy and Buildings
Volume196
Issue number1 August
Pages (from-to)255-268
Number of pages14
ISSN0378-7788
DOIs
Publication statusPublished - 1 Aug 2019

Keywords

  • wind-driven rain
  • in situ measurements
  • internal insulation
  • moisture transport
  • Hygrothermal performance
  • Wind-driven rain
  • In situ measurements
  • Internal insulation
  • Moisture transport

Fingerprint

Dive into the research topics of 'The effects of wind-driven rain on the hygrothermal conditions behind wooden beam ends and at the interfaces between internal insulation and existing solid masonry'. Together they form a unique fingerprint.