Ultrasonographic assessment of patellar tendon thickness at 16 clinically relevant measurement sites – A study of intra- and interrater reliability

P.M. Holm, S.T. Skou, J.L. Olesen, S. Mølbak, H. Jørgensen, M. Skjoldager, S.W. Christensen

Research output: Contribution to journalJournal articleResearchpeer-review

4 Citations (Scopus)
69 Downloads (Pure)

Abstract

Objectives: To determine intra- and interrater reliability of ultrasonographic imaging (USI) measurements of patellar tendon (PT) thickness using 16 measurement sites covering the entire tendon. Design: Reliability study. Setting: Physiotherapy outpatient clinic. Participants: Twenty healthy and physically active volunteers (9 women). Mean age: 24 years (SD ± 2.73). Mean body mass: 75.8 kg (SD ± 11.8). Main outcome measures: Intraclass correlation coefficient (ICC) and 95% limits of agreement (LOA) in cm and in percentage relative to the mean PT thickness. Results: Intrarater reliability ranged from 0.59 to 0.87 and 0.59 to 0.93 for examiners I and II, respectively. Interrater reliability ranged from 0.37 to 0.89. Measurement precision for examiner I ranged from 0.05 to 0.09 cm (17.5%–26.7%) while ranging from 0.04 to 0.13 cm (13.3%–38.7%) for examiner II. Interrater measurement precision ranged from 0.07 to 0.15 cm (19.1%–42.5%). Conclusion: In an attempt to replicate daily clinical USI practice, this was the first study extensively assessing reliability throughout the full range of the patellar tendon - revealing a considerable variation in intra- and interrater reliability as well as measurement precision throughout the 16 individual PT sites. In a clinical context, the low interrater reliability and precision found at the proximal tendon insertion site may have implications for USI of the symptomatic PT, as this is the site mainly associated with underlying pathologic changes. Further reliability studies are needed to clarify the region-specific reliability of the full length PT.

Original languageEnglish
JournalJournal of Bodywork and Movement Therapies
Volume23
Issue number2
Pages (from-to)344-351
Number of pages8
ISSN1360-8592
DOIs
Publication statusPublished - Apr 2019

Keywords

  • Knee
  • Musculoskeletal disorders
  • Patellar tendon
  • Reliability
  • Ultrasonography

Fingerprint

Dive into the research topics of 'Ultrasonographic assessment of patellar tendon thickness at 16 clinically relevant measurement sites – A study of intra- and interrater reliability'. Together they form a unique fingerprint.

Cite this