Abstract

This paper presents a three-phase electric drive with a modified electronic smoothing inductor (MESI) having reduced size of passive components. The classical electronic smoothing inductor (ESI) is able to control a diode bridge output current and also reduce not only mains current harmonics but also output voltage ripple. ESI performs the function of an inductor that has controlled variable impedance. MESI requires active switches with lower ratings than ESI and has the same performance. In MESI, an active voltage source realized by a low-voltage switch-mode converter stage is inserted in series with DC-link capacitor. This increases power factor (PF) and reduces the total harmonic distortions (THDs) in current at mains. Input currents of the diode bridge which usually show high peak amplitudes are converted into a 120° rectangular shape which ideally results in a total PF of 0.955 and THDs of 31%, by electronic smoothing techniques.
Original languageEnglish
Title of host publicationProceedings of the IEEE Energy Conversion Congress and Exposition (ECCE)
Number of pages5
PublisherIEEE Press
Publication dateSept 2010
Pages4199 - 4203
ISBN (Print)978-1-4244-5286-6
DOIs
Publication statusPublished - Sept 2010
EventIEEE Energy Conversion Congress and Exposition, ECCE 2010 - Atlanta, United States
Duration: 12 Sept 201016 Sept 2010

Conference

ConferenceIEEE Energy Conversion Congress and Exposition, ECCE 2010
Country/TerritoryUnited States
CityAtlanta
Period12/09/201016/09/2010

Keywords

  • AC-DC power conversion
  • Active filter
  • DC-AC power conversion
  • Motor Drives
  • Multilevel system

Fingerprint

Dive into the research topics of 'Three-phase electric drive with modified electronic smoothing inductor'. Together they form a unique fingerprint.

Cite this