Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy

Uimin Choi, Frede Blaabjerg, Kyo-Beum Lee

Research output: Contribution to journalJournal articleResearchpeer-review

236 Citations (Scopus)

Abstract

This paper proposes a fault-tolerant control strategy for a T-type three-level inverter when an open-circuit fault occurs. The proposed method is explained by dividing fault into two cases: the faulty condition of half-bridge switches and neutral-point switches. In case of the open-circuit fault in a neutral-point switch, two methods will be proposed and compared based on thermal analysis and neutral-point voltage oscillation. The reliability of T-type inverter systems is improved considerably by the proposed algorithm when a switch fails. The proposed method does not require any additional components. Simulation and experimental results verify the validity and feasibility of the proposed fault-tolerant control strategy.
Original languageEnglish
JournalI E E E Transactions on Power Electronics
Volume30
Issue number5
Pages (from-to)2660 - 2673
Number of pages14
ISSN0885-8993
DOIs
Publication statusPublished - May 2015

Keywords

  • Fault-tolerance
  • Multilevel
  • Reliability
  • Sspace-vector modulation
  • T-type inverter

Fingerprint

Dive into the research topics of 'Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy'. Together they form a unique fingerprint.

Cite this