Reliability of pulse diagnosis in traditional Indian Ayurveda medicine

Vrinda Hitendra Kurande, Rasmus Waagepetersen, Egon Toft, Ramjee Prasad

Research output: Contribution to journalConference abstract in journalResearchpeer-review

Abstract

In Ayurveda, pulse diagnosis is an important diagnostic method to assess the status of three doshas (bio-entity: vata, pitta and kapha) in the patient. However, this is only justifiable if this method is reliable. The aim of this study is to test the intra-rater and inter-rater reliability of pulse diagnosis in Ayurveda. A double-blinded, controlled clinical trial was conducted at Sri Sri College of Ayurvedic Science & Research Hospital, Bangalore, India. 15 Ayurvedic doctors examined the pulse of the 20 healthy subjects (10 male and 10 female) twice in a random order without seeing them. Doctors diagnosed various combinations of three bio-entities vata, pitta and kapha based on the qualitative description of pulse pattern in Ayurveda. Cohen's weighted kappa statistic was used as a measure of reliability and hypothesis of homogeneous diagnosis (random rating) was tested. The level of weighted kappa statistics for each doctor was -0.18, 0.12, 0.31, -0.02, 0.48, 0.1, 0.26, 0.2, 0.34, 0.15, 0.56, 0.03, 0.36, 0.21, 0.4 respectively and the hypothesis of homogeneous diagnosis was only significant (p = 0.04) at the 5 % level for one doctor. The kappa values are in general bigger for the group of practitioners who used pulse diagnosis in their practice (p-value 0.04). Moreover, the proportions of ratings were significantly different among doctors (p-values< 0.0005) both when considering all doctors and within the subgroups of non-practitioners, practitioners of pulse diagnosis and pulse diagnosis course takers. Furthermore, doctors diagnosed more frequently combinations of two doshas. Result shows that the kappa values for each doctor range from slight to moderate level of agreement and are even negative for 2 doctors. Moreover, not much evidence was found against the null hypothesis of homogeneous diagnosis demonstrates the low intra-rater reliability of pulse diagnosis; which potentially suggests inconsistency in the pulse diagnosis. The doctors moreover seem to favor different diagnoses since the proportions of ratings vary among doctors, so reproducibility was hard to reach. Moderate level of agreement is observed in the doctors who are more experienced and practicing pulse diagnosis. This variability in the diagnosis indicates the need of standardization of the pulse diagnosis method in Ayurveda
Original languageEnglish
JournalForschende Komplementaermedizin
Volume20
Issue numberSuppl. 1
Pages (from-to)86-87, No. 303
ISSN1661-4119
Publication statusPublished - 2013
Eventin8th annual congress of the International Society for Complementary Medicine Research (ISCMR) - London , United Kingdom
Duration: 11 Apr 201313 Apr 2013
Conference number: 8

Conference

Conferencein8th annual congress of the International Society for Complementary Medicine Research (ISCMR)
Number8
Country/TerritoryUnited Kingdom
CityLondon
Period11/04/201313/04/2013

Keywords

  • Integrated medicine
  • Indian traditional Medicine

Fingerprint

Dive into the research topics of 'Reliability of pulse diagnosis in traditional Indian Ayurveda medicine'. Together they form a unique fingerprint.

Cite this