Abstract
In this paper, a double phase-shift control strategy is proposed for the full-bridge three-level (FBTL) DC/DC converter applied into DC distribution systems with the medium DC bus voltage. By utilizing the proposed control strategy, the voltage change rate dv/dt and voltage stress of the transformer can be effectively reduced, which means that the reliability and EMC of the FBTL DC/DC converter can be improved. The operation principle and performances of the proposed control strategy is analyzed in detail. Finally, the simulation results are presented to verify the proposed control strategy.
Original language | English |
---|---|
Title of host publication | Proceeding of The 42nd Annual Conference of IEEE Industrial Electronics Society, IECON |
Number of pages | 6 |
Publisher | IEEE Press |
Publication date | Oct 2016 |
Pages | 1202 - 1207 |
ISBN (Electronic) | 978-1-5090-3474-1 |
DOIs | |
Publication status | Published - Oct 2016 |
Event | 42nd Conference of the Industrial Electronics Society, IECON 2016: 42nd Annual Conference of the IEEE Industrial Electronics Society - Palazzo dei Congressi, Florence, Italy Duration: 24 Oct 2016 → 27 Oct 2016 http://www.iecon2016.org/?jjj=1471434927195 http://www.iecon2016.org/ |
Conference
Conference | 42nd Conference of the Industrial Electronics Society, IECON 2016 |
---|---|
Location | Palazzo dei Congressi |
Country/Territory | Italy |
City | Florence |
Period | 24/10/2016 → 27/10/2016 |
Sponsor | IEEE Industrial Electronics Society (IES), Institute of Electrical and Electronics Engineers (IEEE) |
Internet address |
Keywords
- Full-bridge
- Medium DC bus voltage
- Phase-shift control
- Three-level DC/DC converter