@book{805aabd0779211de9240000ea68e967b,
title = "Mechanical Properties of High Performance Cementitious Grout (II)",
abstract = "The present report is an update of the report “Mechanical Properties of High Performance Cementitious Grout (I)” [1] and describes tests carried out on the high performance grout MASTERFLOW 9500, marked “WMG 7145 FP”, developed by BASF Construction Chemicals A/S and designed for use in grouted connections of offshore windmill foundations.",
keywords = "Flow, Fatigue Behaviour, Flexural Strength, Compressive Strength, Setting Time, Grout, Flow, Setting Time, Compressive Strength, Flexural Strength, Fatigue Behaviour, Grout",
author = "S{\o}rensen, {Eigil V.}",
note = "Confidential report",
year = "2009",
language = "English",
series = "DCE Contract Reports",
publisher = "Department of Civil Engineering, Aalborg University",
number = "66",
address = "Denmark",
}