Abstract
Partial shading is one of the biggest challenges in the optimum utilization of photovoltaic (PV) panels. Occurrence of shade on the front side of a panel affects the light transmission completely or partially, leading to its production loss. Hence, in this article, to improve the electrical performance of the partially shaded solar panel, a physical-array-reconfiguration-based novel twisted two-step technique is proposed. The effectiveness of the proposed methodology is verified by utilizing three shade patterns at various locations of the panel. A comparative analysis with various prominent methods in terms of four critical performance metrics is carried out. Furthermore, an experimental study conducted on a 3 × 3 PV array reveals that the output power has increased by 41% by the reconfiguration technique.
Original language | English |
---|---|
Article number | 9712260 |
Journal | I E E E Journal of Photovoltaics |
Volume | 12 |
Issue number | 3 |
Pages (from-to) | 871-879 |
Number of pages | 9 |
ISSN | 2156-3381 |
DOIs | |
Publication status | Published - May 2022 |
Bibliographical note
Publisher Copyright:IEEE
Keywords
- Partial shading (PS)
- photovoltaic (PV)
- physical array reconfiguration (PAR)
- power generation enhancement
- twisted two-step arrangement