Grid-Current-Feedback Control for LCL-Filtered Grid Converters With Enhanced Stability

Zhen Xin, Xiongfei Wang, Poh Chiang Loh, Frede Blaabjerg

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

163 Citationer (Scopus)

Abstract

This paper proposes a Second-Order-Generalized- Integrator (SOGI)-based time delay compensation method for extending the stable region of dual-loop Grid-Current-Feedback (GCF) control system. According to the analysis, stable region of the dual-loop system should be designed below a certain critical frequency, before time delay compensation method can be applied. To always meet the requirement, relationship between single-loop converter-current-feedback and dual-loop GCF control is clarified, before a robust inner-loop gain for the dualloop GCF scheme is determined. Enforcing this gain allows the converter to remain in its stable region, regardless of how its LCL-filter parameters and grid impedance vary. The SOGIbased delay compensation method can then be applied for widening the stable region of the dual-loop GCF scheme, as proven through s-domain Bode diagrams and z-domain root loci. These theoretical proofs are eventually validated by experimental results obtained in the laboratory.
OriginalsprogEngelsk
TidsskriftI E E E Transactions on Power Electronics
Vol/bind32
Udgave nummer4
Sider (fra-til)3216 - 3228
Antal sider13
ISSN0885-8993
DOI
StatusUdgivet - apr. 2017

Fingeraftryk

Dyk ned i forskningsemnerne om 'Grid-Current-Feedback Control for LCL-Filtered Grid Converters With Enhanced Stability'. Sammen danner de et unikt fingeraftryk.

Citationsformater