Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty—an in vivo randomized controlled study of gait using dynamic radiostereometry

Emil Toft Petersen*, Søren Rytter, Daan Koppens, Jesper Dalsgaard, Torben Bæk Hansen, Michael Skipper Andersen, Maiken Stilling

*Kontaktforfatter

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

2 Citationer (Scopus)

Abstract

Purpose: New total knee arthroplasty implant designs attempt to normalize kinematics patterns that may improve functional performance and patient satisfaction. It was hypothesized that a more medial congruent (MC) anatomic bearing design (1) influences the tibiofemoral kinematics and (2) enhances articular congruency compared to a standard symmetrical cruciate retaining (CR) bearing design. Methods: In this double-blinded randomized study, 66 patients with knee osteoarthritis were randomly included in two groups: MC (n = 31) and CR (n = 33). Clinical characteristics such as knee ligament lesions and knee osteoarthritis scores were graded on preoperative magnetic resonance imaging and radiography. At the 1-year follow-up, dynamic radiostereometric analysis was used to assess tibiofemoral joint kinematics and articulation congruency. Patient-reported outcome measures, Oxford Knee Score, the Forgotten Joint Score, and the Knee Osteoarthritis Outcome Score, were assessed preoperatively and at the 1-year follow-up. Results: Compared to the CR bearing, the MC bearing displayed an offset with approximately 3 mm greater anterior tibial drawer (p < 0.001) during the entire motion, and up to approximately 3.5 degrees more tibial external rotation (p = 0.004) from mid-swing to the end of the gait cycle at the 1-year follow-up. Furthermore, the congruency area in the joint articulation was larger during approximately 80% of the gait cycle for the MC bearing compared to the CR. The patient-reported outcome measures improved (p < 0.001), but there were no differences between groups. In addition, there were no differences in clinical characteristics and there were no knee revisions or recognized deep infections during follow-up. Conclusion: The study demonstrates that the MC-bearing design changes tibiofemoral kinematics and increases the area of congruency towards more native knee kinematics than the CR bearing. In perspective this may contribute to a more stabilized knee motion, restoring the patient’s confidence in knee function during daily activities.

OriginalsprogEngelsk
TidsskriftKnee Surgery, Sports Traumatology, Arthroscopy
Vol/bind31
Udgave nummer3
Sider (fra-til)933-945
Antal sider13
ISSN0942-2056
DOI
StatusUdgivet - mar. 2023

Bibliografisk note

© 2022. The Author(s) under exclusive licence to European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA).

Fingeraftryk

Dyk ned i forskningsemnerne om 'Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty—an in vivo randomized controlled study of gait using dynamic radiostereometry'. Sammen danner de et unikt fingeraftryk.

Citationsformater