TY - JOUR
T1 - The validity of smartphone-based spatiotemporal gait measurements during walking with and without head turns
T2 - Comparison with the GAITRite® system
AU - Olsen, Sharon
AU - Rashid, Usman
AU - Barbado, David
AU - Suresh, Priyadharshini
AU - Alder, Gemma
AU - Khan Niazi, Imran
AU - Taylor, Denise
N1 - Copyright © 2023 The Author(s). Published by Elsevier Ltd.. All rights reserved.
PY - 2024/1
Y1 - 2024/1
N2 - Smartphone accelerometry has potential to provide clinicians with specialized gait analysis not available in most clinical settings. The Gait&Balance Application (G&B App) uses smartphone accelerometry to assess spatiotemporal gait parameters under two conditions: walking looking straight ahead and walking with horizontal head turns. This study investigated the validity of G&B App gait parameters compared with the GAITRite® pressure-sensitive walkway. Healthy young and older adults (age range 21-85 years) attended a single session where a smartphone was secured over the lumbosacral junction. Data were collected concurrently with the app and GAITRite® systems as participants completed the two walking conditions. Spatiotemporal gait parameters for 54 participants were determined from both systems and agreement evaluated with partial Pearson's correlation coefficients and limits of agreement. The results demonstrated moderate to excellent validity for G&B App measures of step time (rp 0.97, 95 % CI [0.96, 0.98]), walking speed (rp 0.83 [0.78, 0.87]), and step length (rp 0.74, [0.66, 0.80]) when walking looking straight ahead, and results were comparable with head turns. The validity of walking speed and step length measures was influenced by sex and height. G&B App measures of step length variability, step time variability, step length asymmetry, and step time asymmetry had poor validity. The G&B App has potential to provide valid measures of unilateral and bilateral step time, unilateral and bilateral step length, and walking speed, under two walking conditions in healthy young and older adults. Further research should validate this tool in clinical conditions and optimise the algorithm for demographic characteristics.
AB - Smartphone accelerometry has potential to provide clinicians with specialized gait analysis not available in most clinical settings. The Gait&Balance Application (G&B App) uses smartphone accelerometry to assess spatiotemporal gait parameters under two conditions: walking looking straight ahead and walking with horizontal head turns. This study investigated the validity of G&B App gait parameters compared with the GAITRite® pressure-sensitive walkway. Healthy young and older adults (age range 21-85 years) attended a single session where a smartphone was secured over the lumbosacral junction. Data were collected concurrently with the app and GAITRite® systems as participants completed the two walking conditions. Spatiotemporal gait parameters for 54 participants were determined from both systems and agreement evaluated with partial Pearson's correlation coefficients and limits of agreement. The results demonstrated moderate to excellent validity for G&B App measures of step time (rp 0.97, 95 % CI [0.96, 0.98]), walking speed (rp 0.83 [0.78, 0.87]), and step length (rp 0.74, [0.66, 0.80]) when walking looking straight ahead, and results were comparable with head turns. The validity of walking speed and step length measures was influenced by sex and height. G&B App measures of step length variability, step time variability, step length asymmetry, and step time asymmetry had poor validity. The G&B App has potential to provide valid measures of unilateral and bilateral step time, unilateral and bilateral step length, and walking speed, under two walking conditions in healthy young and older adults. Further research should validate this tool in clinical conditions and optimise the algorithm for demographic characteristics.
KW - Accelerometer
KW - Gait
KW - Gait&Balance App
KW - Smartphone
KW - Validity
U2 - 10.1016/j.jbiomech.2023.111899
DO - 10.1016/j.jbiomech.2023.111899
M3 - Journal article
C2 - 38128468
SN - 0021-9290
VL - 162
JO - Journal of Biomechanics
JF - Journal of Biomechanics
M1 - 111899
ER -