Projekter pr. år
Abstract
This paper proposes a new diagnosis method of an open-switch fault and fault-tolerant control strategy for T-type three-level inverter systems. The location of faulty switch can be identified by the average of normalized phase current and the change of the neutral-point voltage. The proposed fault-tolerant strategy is explained by dividing into two cases: the faulty condition of half-bridge switches and the neutral-point switches. The performance of the T-type inverter system improves considerably by the proposed fault tolerant algorithm when a switch fails. The roposed method does not require additional components and complex calculations. Simulation and experimental results verify the feasibility of the proposed fault diagnosis and fault-tolerant control strategy.
Originalsprog | Engelsk |
---|---|
Tidsskrift | I E E E Transactions on Industry Applications |
Vol/bind | 50 |
Udgave nummer | 1 |
Sider (fra-til) | 495-508 |
Antal sider | 14 |
ISSN | 0093-9994 |
DOI | |
Status | Udgivet - jan. 2014 |
Emneord
- Multilevel
- T-type inverter
- Fault-tolerance
- Open-switch fault
- Reliability
Fingeraftryk
Dyk ned i forskningsemnerne om 'Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-type Three-Level Inverter Systems'. Sammen danner de et unikt fingeraftryk.Projekter
- 1 Afsluttet
-
Center Of Reliable Power Electronics (CORPE)
Blaabjerg, F., Munk-Nielsen, S., Pedersen, K. & Popok, V.
01/04/2011 → 31/12/2016
Projekter: Projekt › Forskning