Double-Skin Facade: Modelling and Experimental Investigations of Thermal Performance

Publikation: Bog/antologi/afhandling/rapportPh.d.-afhandlingForskning

1410 Downloads (Pure)

Resumé

Double-Skin Facades (DSF) are gaining popularity that, in fact, appears to be independent from sturdy critics of the concept in the past years. DSF buildings are being built in Europe and worldwide, DSF concept is being taught at schools of architecture and fully glazed office buildings are being favored by companies and their employees.

To bring the reduction of energy use in these buildings application of suitable tools and methods is necessary to achieve successful design solutions.

Earlier work on the topic of DSF modelling was examined from various publications. As a result, the main difficulties experienced by scientists when attempting to model DSF thermal and energy performance were examined. In addition, the lack of experimental studies and empirical validation of models was realized, many numerical models have not been empirically validated and most of them require an expert knowledge to perform the simulations.

To fill in the gap of lacking experimental data a range of measurements was carried out in an outdoor, double-skin façade full-scale test facility ‘The Cube'. As a result, three complete sets of experimental data were composed. These are available for external air curtain, transparent insulation and preheating operation modes of DSF cavity. The data sets include measurements of naturally induced air flow, temperature gradients, velocity profiles, climate data, etc.

Two data sets were used for further empirical validation of building simulation software for DSF modelling within IEA Annex 34/43, subtask E "Double-Skin Facade". The results of empirical validation are discussed in this work.

Discussion and analysis of experimental results is carried out. It has lead to hypothesis of recirculation flow phenomenon in the DSF cavity. Finally, a suggestion of a new numerical model is developed to account for recirculation flow appearance in the DSF cavity. The model is based on a simple mass balance between the boundary layer flow and the main flow in the cavity.
OriginalsprogEngelsk
Udgivelses stedAalborg
ForlagDepartment of Civil Engineering, Aalborg University
Antal sider212
StatusUdgivet - 2008
NavnDCE Thesis
Nummer17
ISSN1901-7294

Fingerprint

Facades
Skin
Numerical models
Hot Temperature
Air curtains
Office buildings
Boundary layer flow
Preheating
Test facilities
Thermal gradients
Insulation
Personnel

Emneord

  • DSF
  • DSF Cavity
  • Thermal Performance
  • Energy Performance
  • Energy Reduction
  • Double skin façade
  • Full scale tests
  • IEA Annex 34/43
  • The Cube

Citer dette

Kalyanova, O. (2008). Double-Skin Facade: Modelling and Experimental Investigations of Thermal Performance. Aalborg: Department of Civil Engineering, Aalborg University. DCE Thesis, Nr. 17
Kalyanova, Olena. / Double-Skin Facade : Modelling and Experimental Investigations of Thermal Performance. Aalborg : Department of Civil Engineering, Aalborg University, 2008. 212 s. (DCE Thesis; Nr. 17).
@phdthesis{bd6782e0e60711ddb0a4000ea68e967b,
title = "Double-Skin Facade: Modelling and Experimental Investigations of Thermal Performance",
abstract = "Double-Skin Facades (DSF) are gaining popularity that, in fact, appears to be independent from sturdy critics of the concept in the past years. DSF buildings are being built in Europe and worldwide, DSF concept is being taught at schools of architecture and fully glazed office buildings are being favored by companies and their employees. To bring the reduction of energy use in these buildings application of suitable tools and methods is necessary to achieve successful design solutions. Earlier work on the topic of DSF modelling was examined from various publications. As a result, the main difficulties experienced by scientists when attempting to model DSF thermal and energy performance were examined. In addition, the lack of experimental studies and empirical validation of models was realized, many numerical models have not been empirically validated and most of them require an expert knowledge to perform the simulations.To fill in the gap of lacking experimental data a range of measurements was carried out in an outdoor, double-skin fa{\cc}ade full-scale test facility ‘The Cube'. As a result, three complete sets of experimental data were composed. These are available for external air curtain, transparent insulation and preheating operation modes of DSF cavity. The data sets include measurements of naturally induced air flow, temperature gradients, velocity profiles, climate data, etc.Two data sets were used for further empirical validation of building simulation software for DSF modelling within IEA Annex 34/43, subtask E {"}Double-Skin Facade{"}. The results of empirical validation are discussed in this work.Discussion and analysis of experimental results is carried out. It has lead to hypothesis of recirculation flow phenomenon in the DSF cavity. Finally, a suggestion of a new numerical model is developed to account for recirculation flow appearance in the DSF cavity. The model is based on a simple mass balance between the boundary layer flow and the main flow in the cavity.",
keywords = "Double skin fa{\cc}ade, DSF modelling, Energy reduction, Emperical validation, The Cube, Full scale tests, IEA Annex 34/43, Thermal Performance, DSF, DSF Cavity, Thermal Performance, Energy Performance, Energy Reduction, Double skin fa{\cc}ade, Full scale tests, IEA Annex 34/43, The Cube",
author = "Olena Kalyanova",
year = "2008",
language = "English",
series = "DCE Thesis",
publisher = "Department of Civil Engineering, Aalborg University",
number = "17",
address = "Denmark",

}

Kalyanova, O 2008, Double-Skin Facade: Modelling and Experimental Investigations of Thermal Performance. DCE Thesis, nr. 17, Department of Civil Engineering, Aalborg University, Aalborg.

Double-Skin Facade : Modelling and Experimental Investigations of Thermal Performance. / Kalyanova, Olena.

Aalborg : Department of Civil Engineering, Aalborg University, 2008. 212 s. (DCE Thesis; Nr. 17).

Publikation: Bog/antologi/afhandling/rapportPh.d.-afhandlingForskning

TY - BOOK

T1 - Double-Skin Facade

T2 - Modelling and Experimental Investigations of Thermal Performance

AU - Kalyanova, Olena

PY - 2008

Y1 - 2008

N2 - Double-Skin Facades (DSF) are gaining popularity that, in fact, appears to be independent from sturdy critics of the concept in the past years. DSF buildings are being built in Europe and worldwide, DSF concept is being taught at schools of architecture and fully glazed office buildings are being favored by companies and their employees. To bring the reduction of energy use in these buildings application of suitable tools and methods is necessary to achieve successful design solutions. Earlier work on the topic of DSF modelling was examined from various publications. As a result, the main difficulties experienced by scientists when attempting to model DSF thermal and energy performance were examined. In addition, the lack of experimental studies and empirical validation of models was realized, many numerical models have not been empirically validated and most of them require an expert knowledge to perform the simulations.To fill in the gap of lacking experimental data a range of measurements was carried out in an outdoor, double-skin façade full-scale test facility ‘The Cube'. As a result, three complete sets of experimental data were composed. These are available for external air curtain, transparent insulation and preheating operation modes of DSF cavity. The data sets include measurements of naturally induced air flow, temperature gradients, velocity profiles, climate data, etc.Two data sets were used for further empirical validation of building simulation software for DSF modelling within IEA Annex 34/43, subtask E "Double-Skin Facade". The results of empirical validation are discussed in this work.Discussion and analysis of experimental results is carried out. It has lead to hypothesis of recirculation flow phenomenon in the DSF cavity. Finally, a suggestion of a new numerical model is developed to account for recirculation flow appearance in the DSF cavity. The model is based on a simple mass balance between the boundary layer flow and the main flow in the cavity.

AB - Double-Skin Facades (DSF) are gaining popularity that, in fact, appears to be independent from sturdy critics of the concept in the past years. DSF buildings are being built in Europe and worldwide, DSF concept is being taught at schools of architecture and fully glazed office buildings are being favored by companies and their employees. To bring the reduction of energy use in these buildings application of suitable tools and methods is necessary to achieve successful design solutions. Earlier work on the topic of DSF modelling was examined from various publications. As a result, the main difficulties experienced by scientists when attempting to model DSF thermal and energy performance were examined. In addition, the lack of experimental studies and empirical validation of models was realized, many numerical models have not been empirically validated and most of them require an expert knowledge to perform the simulations.To fill in the gap of lacking experimental data a range of measurements was carried out in an outdoor, double-skin façade full-scale test facility ‘The Cube'. As a result, three complete sets of experimental data were composed. These are available for external air curtain, transparent insulation and preheating operation modes of DSF cavity. The data sets include measurements of naturally induced air flow, temperature gradients, velocity profiles, climate data, etc.Two data sets were used for further empirical validation of building simulation software for DSF modelling within IEA Annex 34/43, subtask E "Double-Skin Facade". The results of empirical validation are discussed in this work.Discussion and analysis of experimental results is carried out. It has lead to hypothesis of recirculation flow phenomenon in the DSF cavity. Finally, a suggestion of a new numerical model is developed to account for recirculation flow appearance in the DSF cavity. The model is based on a simple mass balance between the boundary layer flow and the main flow in the cavity.

KW - Double skin façade

KW - DSF modelling

KW - Energy reduction

KW - Emperical validation

KW - The Cube

KW - Full scale tests

KW - IEA Annex 34/43

KW - Thermal Performance

KW - DSF

KW - DSF Cavity

KW - Thermal Performance

KW - Energy Performance

KW - Energy Reduction

KW - Double skin façade

KW - Full scale tests

KW - IEA Annex 34/43

KW - The Cube

M3 - Ph.D. thesis

T3 - DCE Thesis

BT - Double-Skin Facade

PB - Department of Civil Engineering, Aalborg University

CY - Aalborg

ER -

Kalyanova O. Double-Skin Facade: Modelling and Experimental Investigations of Thermal Performance. Aalborg: Department of Civil Engineering, Aalborg University, 2008. 212 s. (DCE Thesis; Nr. 17).