TY - GEN
T1 - Measurements of indoor environmental quality and energy performance of 6 European zero carbon houses - A case study from the first house
AU - Foldbjerg, Peter
AU - Hansen, Ellen Kathrine
AU - Feifer, Lone
AU - Duer, Karsten
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2011
Y1 - 2011
N2 - Home for Life is the first of six single-family houses in the ModelHome 2020 project, an experiment which investigates how good IEQ and energy performance can be achieved with specific measures. A family has occupied Home for Life for a year, and the detailed measurements of daylight, indoor climate and energy performance from the first year are reported. The house will be zero carbon based on an energy optimized design and building components and building-integrated production of energy. Daylight conditions are good, based on both qualitative interviews with the family and measurements of daylight factor in the main rooms. IAQ and thermal conditions are acceptable with further options for optimisations. The family express satisfaction with the house and emphasize the daylight conditions and the fresh air from natural ventilation when they describe their experiences. The target of good IEQ and energy performance is achieved.
AB - Home for Life is the first of six single-family houses in the ModelHome 2020 project, an experiment which investigates how good IEQ and energy performance can be achieved with specific measures. A family has occupied Home for Life for a year, and the detailed measurements of daylight, indoor climate and energy performance from the first year are reported. The house will be zero carbon based on an energy optimized design and building components and building-integrated production of energy. Daylight conditions are good, based on both qualitative interviews with the family and measurements of daylight factor in the main rooms. IAQ and thermal conditions are acceptable with further options for optimisations. The family express satisfaction with the house and emphasize the daylight conditions and the fresh air from natural ventilation when they describe their experiences. The target of good IEQ and energy performance is achieved.
KW - Active house
KW - Daylight
KW - IEQ
KW - Measurements
KW - Zero carbon buildings
UR - http://www.scopus.com/inward/record.url?scp=84880552677&partnerID=8YFLogxK
M3 - Article in proceeding
AN - SCOPUS:84880552677
SN - 9781627482721
T3 - 12th International Conference on Indoor Air Quality and Climate 2011
SP - 1483
EP - 1488
BT - 12th International Conference on Indoor Air Quality and Climate 2011
T2 - 12th International Conference on Indoor Air Quality and Climate 2011
Y2 - 5 June 2011 through 10 June 2011
ER -