Sensitivity and specificity of blood-fluid levels for oral anticoagulant-associated intracerebral haemorrhage

Abeer Almarzouki, Duncan Wilson, Gareth Ambler, Clare Shakeshaft, Hannah Cohen, Tarek Yousry, Rustam Al-Shahi Salman, Gregory Y H Lip, Henry Houlden, Martin M Brown, Keith W Muir, Hans Rolf Jäger, David J Werring

Research output: Contribution to journalJournal articleResearchpeer-review

4 Citations (Scopus)
26 Downloads (Pure)

Abstract

Intracerebral haemorrhage (ICH) is a life-threatening emergency, the incidence of which has increased in part due to an increase in the use of oral anticoagulants. A blood-fluid level within the haematoma, as revealed by computed tomography (CT), has been suggested as a marker for oral anticoagulant-associated ICH (OAC-ICH), but the diagnostic specificity and prognostic value of this finding remains unclear. In 855 patients with CT-confirmed acute ICH scanned within 48 h of symptom onset, we investigated the sensitivity and specificity of the presence of a CT-defined blood-fluid level (rated blinded to anticoagulant status) for identifying concomitant anticoagulant use. We also investigated the association of the presence of a blood-fluid level with six-month case fatality. Eighteen patients (2.1%) had a blood-fluid level identified on CT; of those with a blood-fluid level, 15 (83.3%) were taking anticoagulants. The specificity of blood-fluid level for OAC-ICH was 99.4%; the sensitivity was 4.2%. We could not detect an association between the presence of a blood-fluid level and an increased risk of death at six months (OR = 1.21, 95% CI 0.28-3.88, p = 0.769). The presence of a blood-fluid level should alert clinicians to the possibility of OAC-ICH, but absence of a blood-fluid level is not useful in excluding OAC-ICH.

Original languageEnglish
Article number15529
JournalScientific Reports
Volume10
Issue number1
ISSN2045-2322
DOIs
Publication statusPublished - 23 Sept 2020

Bibliographical note

A correction has been made: https://doi.org/10.1038/s41598-021-88890-5

Correction to: Scientific Reports https://doi.org/10.1038/s41598-020-72504-7, published online 23 September 2020

In the original version of this Article, the author Rustam Al-Shahi Salman was incorrectly indexed. This error has now been corrected.