Mortality and appropriate and inappropriate therapy in patients with ischaemic heart disease and implanted cardioverter-defibrillators for primary prevention: Data from the Danish ICD Register

Peter Weeke*, Jens Brock Johansen, Ole Dan Jørgensen, Jens Cosedis Nielsen, Mogens Møller, Regitze Videbæk, Michael Vinther Højgaard, Sam Riahi, Peter Karl Jacobsen

*Kontaktforfatter

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

54 Citationer (Scopus)

Abstract

AimsTo evaluate the incidences of and risk factors predisposing to appropriate and inappropriate shocks and mortality in a 'real-world' population of patients with ischaemic heart disease (IHD) and implantable cardioverter defibrillators (ICD) for primary prevention of sudden cardiac death (SCD).Methods and resultsIn this nationwide cohort, we prospectively followed 1609 patients with IHD and left ventricular dysfunction from the Danish ICD Register who received an ICD for primary prevention of SCD (1 January 2007 to 30 November 2011). Primary study outcomes were appropriate shocks, inappropriate shocks, and all-cause mortality. Secondary study outcomes included the composite endpoints: appropriate therapy and inappropriate therapy (defined as shock or anti-tachycardia pacing). All-cause mortality was 12.1% during a mean follow-up time of 1.9 ± 1.3 years. Inappropriate shocks and therapy occurred in 2.6% and 3.7% during follow-up, respectively. Appropriate shocks and therapy was identified in 7.8% and 13.4%, respectively. Time-dependent multivariable Cox regression analyses were used to identify risk factors of inappropriate/ appropriate shock, therapy and mortality. Implantation of a dual-chamber ICD was associated with increased risk of both inappropriate shocks and any inappropriate therapy compared to single-chamber ICD [hazard ratios (HR) = 2.45; confidence intervals (CI):1.16-5.14 and HR = 2.38; CI:1.28-4.42, respectively]. No excess risk of mortality was associated with any device type.ConclusionIn this nationwide study of IHD patients with an ICD for primary prevention of SCD, the incidence of appropriate shocks as well as inappropriate shocks were significantly lower than reported in randomized trials. Implantation of a dual-chamber ICD was associated with more inappropriate shocks compared with single chamber devices. Published on behalf of the European Society of Cardiology. All rights reserved.

OriginalsprogEngelsk
TidsskriftEuropace
Vol/bind15
Udgave nummer8
Sider (fra-til)1150-1157
Antal sider8
ISSN1099-5129
DOI
StatusUdgivet - 1 aug. 2013

Fingeraftryk

Dyk ned i forskningsemnerne om 'Mortality and appropriate and inappropriate therapy in patients with ischaemic heart disease and implanted cardioverter-defibrillators for primary prevention: Data from the Danish ICD Register'. Sammen danner de et unikt fingeraftryk.

Citationsformater