Exploration of electrical impedance spectroscopy for monitoring bone healing: a pilot study in rabbits

Markus Winther Frost, Laura Amalie Rytoft, Ming Shen, Yunfeng LI, Stanislav Stefanov Zhekov, Arash Ghaffari, Ben Klauman Kr⊘yer, Gert Fr⊘lund Pedersen, Ole Rahbek, S⊘ren Kold

Publikation: Bidrag til tidsskriftKonferenceabstrakt i tidsskriftForskningpeer review

Abstract

In 2019, Lin et al. published a proof-of-concept study of electrical impedance spectroscopy as a simple and low-cost method to characterize progression of fracture repair (Lin et al., Sci Rep 2019). However, the electrical impedance sensors were placed in the fracture site which may impair the transfer to clinical use. To further explore the concept of monitoring fracture healing by electrical impedance spectroscopy, we established a tibial fracture model in the rabbit where sensors are positioned in proximity to the fracture site but without being placed in the fracture site. The aim of this pilot study was to explore whether distinct patterns of electrical impedance would evolve as tibial fractures in rabbits were evaluated until radiographic signs of healing. Approval was granted from the Inspectorate of the Animal Experimentation under the Danish Ministry of Justice. Four rabbits were anaesthetized, and in each rabbit a tibial osteotomy was made and stabilized by an external fixator. Electrical impedance was measured immediately postoperative and hereafter daily until euthanization after 3 weeks. Recordings were obtained within a wide frequency range (10 Hz to 1 MHz) from an inner electrode placed into the medullary canal and an outer electrode placed extracortical on the lateral with a distance of 3 mm to the defect. A similar pattern of electrical impedance over time was observed in the four rabbits. During the very early stages of fracture healing, an initial fluctuation in electrical impedance occurred. However, after 10 days the curves revealed a steady daily increase in electrical impedance. The first radiological signs of bone healing were detected after 14 days and progressed in all four rabbits in accordance with increments in the electrical impedance until termination of the pilot study after 21 days. Consistent electrical impedance patterns were detected during bone healing in a pilot study of four rabbits. Further research is needed to explore whether the presented method of electrical impedance measurements can be used to monitor bone healing over time.
OriginalsprogEngelsk
TidsskriftOrthopaedic Proceedings
Vol/bind102-B
Udgave nummerSuppl. 11
Sider (fra-til)87
Antal sider1
ISSN2049-4416
DOI
StatusUdgivet - dec. 2020
BegivenhedThe 28th Annual Meeting of the European Orthopaedic Research Society (EORS) - Virtuel konference
Varighed: 17 sep. 202018 sep. 2020
https://eors.info/

Konference

KonferenceThe 28th Annual Meeting of the European Orthopaedic Research Society (EORS)
LokationVirtuel konference
Periode17/09/202018/09/2020
Internetadresse

Citationsformater