Supplementary data for "Hygrothermal performance of six insulation systems for internal retrofitting solid masonry walls"

  • Nickolaj Feldt Jensen (Bidrager)
  • Søren Peter Bjarløv (Ophavsperson)
  • Carsten Rode (Ophavsperson)
  • Birgitte Andersen (Ophavsperson)
  • Eva B Møller (Technical University of Denmark) (Ophavsperson)

Datasæt

Beskrivelse

Supplementary data for: N.F. Jensen, S.P. Bjarløv, C. Rode, B. Andersen, E.B. Møller, 2020, "Hygrothermal performance of a phenolic foam insulation system with a closed cell structure and a lime-cork insulating plaster for internal retrofitting solid masonry walls"The article is in review for Journal of Building PhysicsThe authors are awaiting link/DOI for the article. The datasets comprises: 1) Measured temperature and relative humidity (Hourly data and 96-hour running average).2) Mathematical mould-growth predictions with the VTT model.3) On-site fungal tests with the Mycometer method.4) On-site pH tests5) Photos for installation of the Phenolic foam and lime-cork insulating plaster systems.
Dato for tilgængelighed2020
ForlagTechnical University of Denmark

Citationsformater